| 1000
watt DC/AC inverters |
125 volts
DC to 115 VAC |
125 volts
DC to 220VAC |
250VDC to
115VAC |
250VDC to
220VAC |
Part
Number and Price |
PLVS1000-125-115 Allow
up to 14 days for shipping
$2788
|
PLVS1000-125-220 Allow
up to 14 days for shipping
$2788
|
PLVS1000-250-115 Allow
up to 14 days for shipping
$2788
|
PLVS1000-250-220 Allow
up to 14 days for shipping
$2788
|
| Country of
Origin |
Canada, NAFTA eligible |
Canada, NAFTA eligible |
Canada, NAFTA eligible |
Canada, NAFTA eligible |
| Input Voltage |
100-150VDC |
100-150VDC |
200-300VDC |
200-300VDC |
| Output Voltage |
115VAC |
220VAC |
115VAC |
220VAC |
| Output Frequency |
60 Hz pure sine
wave 50Hz or 400Hz available |
60 Hz pure sine
wave 50Hz or 400Hz available |
60 Hz pure sine
wave 50Hz or 400Hz available |
60 Hz pure sine
wave 50Hz or 400Hz available |
| Max Output
Current(s) |
8.7 Amps 10 minutes
maximum |
8.7 Amps 10 minutes
maximum |
4.34 Amps 10 minutes
maximum |
4.34 Amps 10 minutes
maximum |
| Max Output Power
|
1000 watts |
1000 watts |
1000 watts |
1000 Watts |
| Load Crest
Factor |
3 |
3 |
3 |
3 |
| Output current
limit? |
Yes |
Yes |
Yes |
Yes |
| Operating Temperature
Range |
0°C to +50°C |
0°C to +50°C |
0°C to +50°C |
0°C to +50°C |
| Humidity |
5-95% non-condensing |
5-95% non-condensing |
5-95% non-condensing |
5-95% non-condensing |
| Efficiency |
78 % at full load |
78 % at full load |
78% at full load |
78% at full load |
| Duty Cycle |
Continuous power 24 hours
per day |
Continuous power 24 hours
per day |
Continuous power 24 hours
per day |
Continuous power 24 hours
per day |
| Output
Distortion |
<5% at full load |
<5% at full load |
<5% at full load |
<5% at full load |
| Line Regulation |
< ±0.5% |
< ±0.5% |
< ±0.5% |
< ±0.5% |
| Load regulation |
< ±2% |
< ±2% |
< ±2% |
< ±2% |
| Isolation |
Fully Isolated >2250
volts isolation from case to output
terminals, >3000V between input and
output terminals, >1500V isolation
between input terminals and case,
grounded neutral |
Fully Isolated >2250
volts isolation from case to output
terminals, >3000V between input and
output terminals, >1500V isolation
between input terminals and case,
grounded neutral |
Fully Isolated >2250
volts isolation from case to output
terminals, >3000V between input and
output terminals, >1500V isolation
between input terminals and case,
grounded neutral |
Fully Isolated >2250
volts isolation from case to output
terminals, >3000V between input and
output terminals, >1500V isolation
between input terminals and case,
grounded neutral |
| Remote power
on/off |
No |
No |
No |
|
| Input
Connections |
Compression Terminal |
Compression Terminal |
Compression Terminal |
Compression Terminal |
| Output
Connections |
Standard AC recepticle |
Standard AC recepticle |
Standard AC recepticle |
Standard AC recepticle |
| Protection |
Over Voltage , Over Current,
Short Circuit , Reverse Polarity , Over
Load, thermal shutdonw with automatic
recovery |
Over Voltage , Over Current,
Short Circuit , Reverse Polarity , Over
Load, thermal shutdonw with automatic
recovery |
Over Voltage , Over Current,
Short Circuit , Reverse Polarity , Over
Load, thermal shutdonw with automatic
recovery |
Over Voltage , Over Current,
Short Circuit , Reverse Polarity , Over
Load, thermal shutdonw with automatic
recovery |
| Agency
compliance |
Designed to meet C22.2 No.
107.1 - 01, UL 458 and EN60950 |
Designed to meet C22.2 No.
107.1 - 01, UL 458 and EN60950 |
Designed to meet C22.2 No.
107.1 - 01, UL 458 and EN60950 |
Designed to meet C22.2 No.
107.1 - 01, UL 458 and EN60950 |
| Dimensions |
444 x 444 x
56 mm (17.5
x 17.5 x 2.2 inches) |
444 x 444 x
56 mm (17.5
x 17.5 x 2.2 inches) |
444 x 444 x
56 mm (17.5
x 17.5 x 2.2 inches) |
444 x 444 x
56 mm (17.5
x 17.5 x 2.2 inches) |
| Weight |
8 Kg (17.6
lbs) |
8 Kg (17.6
lbs) |
8 Kg (17.6
lbs) |
8 Kg (17.6
lbs) |
| Cooling |
Fan comes on when
needed |
Fan comes on when
needed |
Fan comes on when
needed |
Fan comes on when
needed |
| Service
life |
10 years |
10 years |
10 years |
10 years |
| Warranty* |
2 years |
2 years |
2 years |
2 years |