| 300 watt DC/AC inverters |
12 volts DC to 110 VAC |
12 volts DC to 220VAC |
24VDC to 110VAC |
24VDC to 220VAC |
Part
Number and Price |
PIPS300-12-110-MS Allow up to 5 days for shipping $779
|
PIPS300-12-220-MS Allow up to 5 days for shipping $779
|
PIPS300-24-110-MS Allow up to 5 days for shipping $779
|
PIPS300-24-220-MS Allow up to 5 days for shipping $779
|
| Country of Origin |
Canada, NAFTA eligible |
Canada, NAFTA eligible |
Canada, NAFTA eligible |
Canada, NAFTA eligible |
| Input Voltage |
10.5-16VDC |
10.5-16VDC |
20-30VDC |
20-30VDC |
| Max Input current at No
Load |
mA |
mA |
mA |
|
| Output Voltage |
115VAC |
220VAC |
115VAC |
220VAC |
| Output Frequency |
60 Hz
pure sine wave |
60 Hz
pure sine wave |
60 Hz
pure sine wave |
60 Hz
pure sine wave |
| Frequency accuracy |
Crystal controlled ±0.01 Hz |
Crystal controlled ±0.01 Hz |
Crystal controlled ±0.01 Hz |
Crystal controlled ±0.01 Hz |
| Max Output Current(s) |
3.3
Amps 10 minutes maximum |
1.82
Amps 10 minutes maximum |
3.3
Amps 10 minutes maximum |
1.82
Amps 10 minutes maximum |
| Max Output Power |
380
watts |
400
watts |
380
watts |
400
Watts |
| Continuous Output Current |
2.5
Amps |
1.36
Amps |
2.5
Amps |
1.36
Amps |
| Continuous Output Power |
287
Watts |
300
Watts |
287
Watts |
300
Watts |
| Output current limit? |
Yes |
Yes |
Yes |
|
| Operating Temperature Range |
-40°C to +50°C (+85°C with derating) |
-40°C to +50°C (+85°C with derating) |
-40°C to +50°C (+85°C with derating) |
-40°C to +50°C (+85°C with derating) |
| Derating |
2.5%
per °C from 50°C to +85°C |
2.5%
per °C from 50°C to +85°C |
2.5%
per °C from 50°C to +85°C |
2.5%
per °C from 50°C to +85°C |
| Humidity |
0-95%
non-condensing |
0-95%
non-condensing |
0-95%
non-condensing |
0-95%
non-condensing |
| Efficiency |
>80 % |
>80 % |
>80 % |
>80 % |
| Duty Cycle |
Peak
power for 10 minutes maximum, continuous power 24 hours per day |
Peak
power for 10 minutes maximum, continuous power 24 hours per day |
Peak
power for 10 minutes maximum, continuous power 24 hours per day |
Peak
power for 10 minutes maximum, continuous power 24 hours per day |
| Output Distortion |
<5% at 300 watts into a 0.8 power factor load |
<5% at 300 watts into a 0.8 power factor load |
<5% at 300 watts into a 0.8 power factor load |
<5% at 300 watts into a 0.8 power factor load |
| Line Regulation |
<
±0.5% |
<
±0.5% |
<
±0.5% |
<
±0.5% |
| Load regulation |
<
±0.5% |
<
±0.5% |
<
±0.5% |
<
±0.5% |
| Isolation |
Fully
Isolated >1500 volts isolation from case to output terminals or between input and output
terminals. >500V isolation between input terminals and case |
Fully
Isolated >1500 volts isolation from case to output terminals or between input and output
terminals. >500V isolation between input terminals and case |
Fully
Isolated >1500 volts isolation from case to output terminals or between input and output
terminals. >500V isolation between input terminals and case |
Fully
Isolated >1500 volts isolation from case to output terminals or between input and output
terminals. >500V isolation between input terminals and case |
| Ground fault current |
<
5 mA between neutral and ground |
<
5 mA between neutral and ground |
<
5 mA between neutral and ground |
<
5 mA between neutral and ground |
| Remote power on/off |
No |
No |
No |
|
| Input Fuse |
|
|
|
|
| Input
Connections |
Screw terminals with cable clamp |
Screw terminals with cable clamp |
Screw terminals with cable clamp |
Screw terminals with cable clamp |
| Output Connections |
Standard AC recepticle |
Standard AC recepticle |
Standard AC recepticle |
Standard AC recepticle |
| Protection |
Over Voltage , Over Current, Short Circuit , Reverse Polarity , Over
Load |
Over Voltage , Over Current, Short Circuit , Reverse Polarity , Over
Load |
Over Voltage , Over Current, Short Circuit , Reverse Polarity , Over
Load |
Over Voltage , Over Current, Short Circuit , Reverse Polarity , Over
Load |
| Agency compliance |
cETLus approved to CSA C22.2 & UL458 |
cETLus approved to CSA C22.2 & UL458 |
cETLus approved to CSA C22.2 & UL458 |
cETLus approved to CSA C22.2 & UL458 |
| Dimensions |
272 x 196 x 132 (10.7 x 7.7 x 5.2 inches) |
272 x 196 x 132 (10.7 x 7.7 x 5.2 inches) |
272 x 196 x 132 (10.7 x 7.7 x 5.2 inches) |
272 x 196 x 132 (10.7 x 7.7 x 5.2 inches) |
| Drawings |
Click Here for Drawing
|
Click Here for Drawing
|
Click Here for Drawing
|
Click Here for Drawing
|
| Weight |
5.5
Kg (12.4 lbs) |
5.5
Kg (12.4 lbs) |
5.5
Kg (12.4 lbs) |
5.5
Kg (12.4 lbs) |
| Audible Noise |
34.5 dB when fan is
operating |
34.5 dB when fan is
operating |
34.5 dB when fan is
operating |
34.5 dB when fan is
operating |
| Cooling |
Fan comes on when
needed |
Fan comes on when
needed |
Fan comes on when
needed |
Fan comes on when
needed |
| Vibration |
Meets MIL-Spec loose
cargo requirement |
Meets MIL-Spec loose
cargo requirement |
Meets MIL-Spec loose
cargo requirement |
Meets MIL-Spec loose
cargo requirement |
| Service life |
10
years |
10
years |
10
years |
10
years |
| Warranty |
3
years |
3
years |
3
years |
3
years |