These are
regulated switching power converters
(switchmode), designed to allow the use
of 9 volt equipment in 12V or 24V
vehicles. These 9V output converters
have been designed to be very rugged
electrically and can be operated
continuously at 75°C (65°C for
the 5A version). These are also
known as 9 volt voltage reducers, and
voltage regulators. Custom output
voltages are available from 3.3VDC to
the input voltage minus 1.5 volts
(10.5VDC for a 12 volt input, 22.5 for
a 24 volt input)
Prices:
PST-DCZ0903
9V 3A
|
|
| Quantity |
Price |
| 1-49 |
$47.60 |
| 50-99 |
$39.70 |
| 100-199 |
$35.08 |
| 200+ |
$33.00 |
PST-DCZ0903-W
weather resistant 9V 3A
|
|
| Quantity |
Price |
| 1-49 |
$61.00 |
| 50-99 |
$50.80 |
| 100-199 |
$44.95 |
| 200+ |
$42.25 |
|
PST-DCZ0905
9V 5A
|
|
| Quantity |
Price |
| 1-49 |
$57.60
|
| 50-99 |
$47.00 |
| 100-199 |
$40.00 |
| 200+ |
$38.20 |
PST-DCZ0905-W
weather resistant 9V 5A
|
|
| Quantity |
Price |
| 1-49 |
$73.80
|
| 50-99 |
$61.50 |
| 100-199 |
$54.40 |
| 200+ |
$51.10 |
|
|
Electrical
Specifications |
| |
3
Amp version |
5
Amp Version |
|
Output Voltage |
9.0 VDC ± 0.1 VDC
|
9.0 VDC ± 0.1
VDC |
|
Readily Available Custom
Output Voltages |
3VDC
to 9VDC |
3VDC
to 9VDC |
|
Maximum steady state input
voltage range |
8 VDC to 41 VDC ** |
8 VDC to 41 VDC ** |
|
Nominal continuous output
current when input voltage is between
8VDC and 20VDC |
3.0A |
5.0A |
|
Line regulation |
± 0.5% |
± 0.5% |
|
Load regulation |
± 1.0% |
± 1.0% |
|
Minimum input voltage for
load regulation of 10 %, see Note 1
|
10.5 VDC (1 minute
duration) |
10.5 VDC (1 minute
duration) |
|
Maximum output ripple
|
10mV p-p |
25mV p-p |
|
Maximum switching noise
level |
90mV p-p |
90mV p-p |
|
Maximum operating
temperature range |
-40°C to 75°C
(-40°F to 167°F) |
-40°C to 65°C
(-40°F to 149°F) |
|
Maximum storage temperature
range |
-40°C to 90°C (-
40°F to 194°F) |
-40°C to 90°C (-
40°F to 194°F) |
|
Minimum efficiency, see
Figure 1 |
78% 24 VDC input, 0.15A
load |
77% 24 VDC input, 1A
load |
|
Maximum efficiency,
see Figure
1 |
89% 12 VDC input, 1.0A
load |
88% 12 VDC input, 1.0A
load |
|
Isolation |
Common ground, the negative
input is tied to the negative output.
The frame is isolated. |
|
Protection |
|
Overload
protection |
If there is a short circuit
connection or other overload connection
is sensed, the unit will automatically
limit the output current and, depending
on severity, will go into a hiccup
mode. See Note 2. |
|
Over temperature
protection |
If an extreme over
temperature condition occurs the unit
will shut down until the temperature is
reduced. See Note 3. |
|
Reverse polarity
protection |
If an
in-line 4A fast acting fuse (5A for the
5A model) is connected as shown in
Figure 2, then the unit will be
protected from reverse polarity
connection. If the fuse is used
and there is a reverse polarity
connection, the fuse will blow and
protect the unit from damage. See Note
4. |
**Note: the
efficiency drops when the input voltage
is above 28 volts, derating either the
maximum abmient temperature or output
current is appropriate when operating
at the higher voltages
|
Physical Specifications
for both models |
|
Weight |
108 grams
or about 3.8 ounces |
|
Dimensions |
|
|
120mm (4.73 inches)
|
|
55mm (2.17 inches)
|
|
33mm (1.30 inches)
|
|
|
Connections
|
|
|
|
|
|
Input connector |
2 position screw terminal
block will accept 14awg to 24 awg
wire |
|
|
Output connector |
2 position screw terminal
block will accept 14awg to 24 awg
wire |
|
| Input
and output connectors for weather
resistant versions |
18AWG Red and
Black wires, 6 inches (15 cm) long |
|
| |
|
|
Note 1: Extended
operation at voltages less than 8.0 VDC
is not recommended although the unit
will work at voltages lower than this
with reduced load regulation. With
voltages lower than 7.0 VDC, output
voltage will drop out until the voltage
is increased.
Note 2: If an
overload is sensed, the unit will
automatically limit the output current
and reduce the output voltage. If the
output voltage is excessively reduced
to limit current, the unit will go into
a hiccup mode and wait until the
overload is removed to restore power.
This dual-mode overload protection
system allows the unit to be protected
from continuous short circuit
connection and other overload
conditions.
Note 3: Extended
operation at temperatures above 75C can
damage the unit and will void the
warranty.
Note 4: If the in-line
4A fast-acting fuse is not connected as
shown in Figure 2, a reverse polarity
connection can damage the unit and will
void the warranty.
Typical
efficiency curve for the 5VDC 3Amp
version
Efficiency curves
for the 5VDC 5Amp DC-DC
converter

Advantages:
Inexpensive
Switchmode DC/DC
Converter.
High
efficiency.
Excellent
line and load
regulation.
Wide input
voltage range. |