| DC-DC
Converters |
Heavy Duty 7
Amp 36V 110VAC Battery Charger
 |
Heavy
Duty 7Amp 36V 220VAC Battery Charger |
Heavy
Duty 16 Amp 36V 110VAC Battery Charger
 |
Heavy
Duty 16 Amp 36V 120VAC Battery Charger
 |
Part Number and Price |
PBCA310-110-36 $693
Allow up to 10 days for shipping |
PBCA310-220-36 $693
Allow up to 10 days for shipping |
PBCA610-110-36 $906
Allow up to 10 days for shipping |
PBCA610-220-36 $906
Allow up to 10 days for shipping |
| Country of Origin |
Canada, NAFTA eligible |
Canada, NAFTA eligible |
Canada, NAFTA eligible |
Canada, NAFTA eligible |
| Nominal Input Voltage |
110VAC |
220VAC |
110VAC |
220VAC |
| Input Voltage Range |
90 - 130 VAC |
180 - 260VAC |
90 - 130 VAC |
180 - 260VAC |
| Absorption Voltage |
43.2V |
43.2V |
| Float Voltage |
41VDC |
|
| Output Voltage Adjustment |
±1V typical |
|
| Max Output Current(s) |
7 Amps |
16 Amps |
| Transition current |
1 Amps |
2.5 Amps |
| Duty Cycle |
100% rated power 24 hours a day |
|
| Reverse Polarity Protection? |
Yes |
Yes |
| Current Limiting? |
Yes |
Yes |
| Over Temperature shutdown? |
Yes |
Yes |
| Short Circuit Protection? |
Yes |
Yes |
| Stages |
2 or 3 user selectable |
2 or 3 user selectable |
| Input Under voltage Shutdown? |
Yes |
Yes |
| Output Overvoltage Crowbar? |
Yes |
Yes |
| Output Crowbar Trigger |
48V ± 1.5V |
48V ± 1.5V |
| Dry Contact Output Fail
Relay? |
Yes |
| Can be left Permanently
Attached? |
Yes |
| Temperature Compensated
Charging? |
Yes |
| Temperature Compensation
Schedule |
-80mV/°C |
| Operating Temperature Range |
-25°C to +40°C |
| Operating Temperature Range with
Derating |
-25°C to +50°C |
| Derating |
2.5% per °C up to +50°C |
2.5% per °C up to +50°C |
2.5% per °C up to +50°C |
2.5% per °C up to +50°C |
| Efficiency |
>75 % |
>75 % |
>75 % |
>75 % |
| Line Regulation |
<±0.5% |
<±0.5% |
<±0.5% |
|
| Load Regulation |
<±0.5% |
<±0.5% |
<±0.5% |
|
| Transient Response |
<2V for 50% surge |
<2V for 50% surge |
<2V for 50% surge |
|
| Switching frequency |
60 kHz |
60 kHz |
60 kHz |
|
| Output ripple noise |
<25 mV rms |
<25 mV rms |
<50 mV rms |
<50 mV rms |
| Isolation |
>1500 volts isolation from case to any input terminal, >500V
isolation between case and any output terminal, >1500 Volts isolation input
to output. Transient voltage suppression. |
| Indicators |
Audio and visual indicators for constant current, low input
voltage, low output voltage, over temperature. Dry Contact output failure
relay. |
| Input Fuse |
5A MDA |
3A MDA |
10A MDA |
5A MDA |
| Output Fuse |
10A AGC |
10A AGC |
20 x 2 ATC |
20 x 2 ATC |
| Input Connection |
AC cord |
AC cord |
AC cord |
AC cord |
| Connections |
4
contact screw terminal |
4
contact screw terminal |
4
contact screw terminal |
4
contact screw terminals |
| Protection |
Over Voltage , Over Current, Short Circuit , Reverse Polarity ,
Over Load |
| Dimensions |
244 x 208 x 64 mm (9.6 x
8.2 x 3.5 inches) |
244 x 208 x 64 mm (9.6 x
8.2 x 3.5 inches) |
368 x 251 x 76 mm (14.5
x 9.9 x 3 inches) |
368 x 251 x 76 mm
(14.5 x 9.9 x 3 inches) |
| Drawings |
Click Here for Drawing |
Click Here for Drawing |
Click Here for Drawing |
Click Here for Drawing |
| Weight |
3.4 Kg (7.5 lbs) |
3.4 Kg (7.5 lbs) |
3.3 Kg (7.2 lbs) |
3.3 Kg (7.2 lbs) |
| Audible Noise |
None |
None |
None |
|
| Typical service life |
87000 hours |
87000 hours |
87000 hours |
|
| Warranty |
3
years |
3
years |
3
years |
3
years |
| Approvals |
Built to meet UL458 and CSA 22.2.107.1 |
Built to meet UL458 and CSA 22.2.107.1 |
Built to meet UL458 and CSA 22.2.107.1 |