| 1200 watt
DC/AC inverters |
300 volts DC to 115 VAC 1200VA |
300 volts DC to 220VAC 1200VA |
300VDC to 115VAC 2400VA |
300VDC to 220VAC 2400VA |
Part Number and
Price |
IPSi1205-250-110 Allow up to 8-12 weeks for manufacturing
$2553
|
IPSi1205-250-220 Allow up to 8-12 weeks for
manufacturing $2639
|
IPSi2405-250-110 Allow up to 8-12 weeks for manufacturing
$3103
|
IPSi2405-250-220 Allow up to 8-12 weeks for manufacturing
$3189
|
| Country of Origin |
Canada, NAFTA eligible |
Canada, NAFTA eligible |
Canada, NAFTA eligible |
Canada, NAFTA eligible |
| Input Voltage |
200-400VDC |
200-400VDC |
200-400VDC |
200-400VDC |
| Input Current |
< 20A |
< 20A |
< 40A |
< 40A |
| Output Voltage |
110VAC ± 2 |
220VAC ±4 |
115VAC ± 2 |
220VAC ± 4 |
| Output Frequency |
60 Hz or 50Hz pure sine wave User selectable frequency |
| Continuous Ouput
Current |
11 Amps |
5.5 Amps |
22 Amps |
11 Amps |
| Peak Output
Current |
22A 10 seconds 13A 60 seconds |
11A 10 seconds 6.5A 60 seconds |
44A 10 seconds 26A 60 seconds |
22A 10 seconds 13A 60 seconds |
| Output Power |
1200 VA |
1200 VA |
2400 VA |
2400 VA |
| Load Crest Factor |
3 |
3 |
3 |
3 |
| Overvoltage protection |
> 400 VDC |
| Undervoltage protection |
< 180 VDC |
| Output current limit? |
Yes |
| Operating Temperature
Range |
0°C to +50°C |
| Humidity |
5-95% non-condensing |
| Efficiency |
80 % minimum at full load |
| Duty Cycle |
Continuous power 24 hours per day |
| Harmonic Distortion |
<5% at full load |
| Line Regulation |
< ±0.5% |
| Load regulation |
< ±6% over the range of 10% load to 100% load |
| Temperature Drift |
<0.05% per °C over operating temperature range |
| Isolation |
1200VDC Input to output 2250VDC, Output to chassis 2250VDC |
| Remote power on/off |
Optional |
|
Connections |
AC OUT 2x - Universal AC Receptable S.203013 AC Out
1x Phoenix VDFK4 terminal block
DC In Phoenix VFK-4 terminal block for
AWG 10-24 wire |
| Wiring
recommenations |
Output AWG 10-20 Input AWG 10-16 |
Output AWG 10-22 Input AWG 10-16 |
Output AWG 10-16 Input AWG 10-12 |
Output AWG 10-20 Input AWG 10-12 |
| Input Protction |
Thermal fuse, Inrush current limiting, Reverse polarity
protection |
| Output Protection |
Current limiting with short circuit protection, thermal shutdown
with automatic recovery in case of continuous overload or insufficient
airflow |
| EMI |
Meets EN55022 Class A |
| Agency compliance |
Compliance to C22.2 No. 107.1 - 01 and UL 458 |
| Dimensions |
5.6 x 11.75 x 18.68 inches 13.5 x 35.1 x 42.5 cm |
| Weight |
24 Kg (52.5 lbs) |
| Cooling |
Fan comes on when needed |
| Warranty* |
5 years *Warranty depends on installation within good
engineering practice. |